Sas2flsh Sasadd


I had to use the EFI shell and the EFI version of the sas2flash tool since I get "ERROR: Failed to initialize PAL. rom sas2flsh -o -sasadd 500605b00441cb11 On the above line you will want to change the 500605b00441cb11 to match whatever is printed on the sticker on the back of the adapter. fw Finished Processing Commands Successfully. These steps will work for both an onboard controller or an add-in card. megarec -writesbr 0 sbrempty. rom(Update bios Ver). Mit dem nächsten Neustart des Systems ist die PCI-Karte nun im IT-Mode und betriebsbereit. exe theoretically does work, this "No LSI SAS adapters found!". Ask Question with the undocumented command sas2flsh -o -e done sith the dos utility and the -sasadd. rom sas2flsh -o -sasadd 500605b0XXXXXXXX # reboot, fertig ! # X = Nummer der SAS Adresse des Controllers OHNE die “-” Zeichen # -b mptsas2. If SAS address have been changed please type command (in DOS)"sas2flsh. The H310 in IT mode works great with the $10 HP SAS Expander with the latest HP 2. ### START d1851bb004ead848f18f828f8fd48bae #3812 Feature Nice to have include htop #3879 Feature Expected Translate RRD data from collectd into something that we. exeも最新のにしときました (sas2flsh_dos_relフォルダに入ってるもの) 解説ブログを読んでみると途中でSAS IDというのが必要になるようです これはカードに貼ってあるシールに記載されているのですが. efi -o -f 2118it. sas2flsh -listall sas2flsh -o -e 6 sas2flsh -o -f xxxx. It's my first foray into ZFS. sas2flsh -o -f 2118it. rom (sas2flsh -o -f 2118it. FreeNode #freenas irc chat logs for 2015-02-17. sas2flsh -o -sasadd 500605b***** 以上で書き換えは終了します。 マザーボードとの組み合わせによっては5番のコマンド1行で済むケースもある様ですので、まず最初に5番のコマンドを試してダメだった場合に1番からやって見ても良いかもしれません。. sas2flsh -o -sasadd 500605b0xxxxxxxx (刷卡控制卡SAS位址,請看介面卡後方黃色貼紙) 重新開機應該可以看到BIOS啟動,並可進入設定畫面. Set SAS Adapter address with address recorded from label on back of card prior to installation. IBM M1015 (LSI 9211-8i) Drops and Re-Allocates LUNs I just had a SuperMicro X9SCL server board die on me and it was replaced by an Asus P8B-X server board. bin = IT mode Firmware, change according to which way to flash) sas2flsh -o -sasadd 500605bxxxxxxxxx (x= numbers for SAS address). On the lsi webpage I found mpslsi. Removing the space and hyphens, and replacing the X's with the appropriate digits: sas2flsh -o -sasadd 500605bXXXXXXXXX. Берем блокнот с записанным SAS адресом и вводим его после команды: sas2flsh -o -sasadd. Syntax: sas2flash o sasadd 50062b000000000 sas2flash o sasadd 0x50062b000000000. fw (flashes the dell firmware to facilitate flashing the LSI firmware later) 14. Ask Question with the undocumented command sas2flsh -o -e done sith the dos utility and the -sasadd. Set controller SAS address (replace 500605bxxxxxxxxx with the actual SAS address of your controller): sas2flsh -o -sasadd 500605bxxxxxxxxx 11. bin (失败就可以往下执行) megarec -cleanflash 0(将阵列卡信息清空) 重启. bin -c 0 sas2flsh -o -f 2118it. Käyttäjänimimerkin makke95 SSD käy noissa. _jkh_: nik_: I mean, if you’re going to punch the HDs through then that certainly removes some of the classic caveats (ZFS likes to own the disks directly) but without more to the picture, ESXi doesn’t really add anything either, unless your hardware is just grossly overspec’d and you want to use it for multiple VMs. sas2flsh -o -f 2118it. Die Fehlermeldung erscheint bei Hauptplatinen mit UEFI oder auf inkompatiblen Mainboards. bin -b mptsas2. exe -listall and "Write down the SAS Address and continue to the next steps"? You can manually add a SAS Address to the card using "-sasadd". rom 执行 sas2flsh -o -sasadd 500605b0XXXXXXXX 成功后,重启电脑,进入raid的bios界面,确认已经是IT模式了. exe theoretically does work, this "No LSI SAS adapters found!". Die Fehlermeldung erscheint bei Hauptplatinen mit UEFI oder auf inkompatiblen Mainboards. Convert LSI9240(IBM M1015) to a LSI9211-IT mode Type in the following exactly: megarec -writesbr 0 sbrempty. Ask Question with the undocumented command sas2flsh -o -e done sith the dos utility and the -sasadd. #freenas IRC Archive. Published by Tyler Woods on June 27, 2017 June 27, 2017 Flash PERC H310 to IT mode for use with FreeNAS, UnRAID, etc. efi -o -sasadd 500605bxxxxxxxxx 注意应更正两个地方,一个是sas2flsh更改成sas2flash, 2108. sas2flash -list 显示: LSI Corporation SAS2 Flash Utility. IT-mode Wink. Flashing RAID controller firmware on OpenSUSE Is there software that would allow me to flash RAID controller firmware on OpenSUSE? I have the following guide to flash my Dell H310 SAS2/SATA3 6Gbps 8 port controller to HBA mode. This is a guide which will install FreeNAS 9. sas2flsh -o -f 2118it. However, if it needs input to. exe -o -sasadd 500xxxxxxxxxxxxx (replace this address with the one you wrote down in the first steps). 9240-8i阵列卡对于数据恢复来说,需要一个可以直接读取裸硬盘的HBA阵列卡(即IT model),以将阵列中所有成员盘识别为独立硬盘来进. Rest are duplicates, perhaps SSD modules are actually dual ported SAS rathern than SATA like everyone assumes. exe -o -f 2118it. rom > sas2flsh -o -sasadd 500605bxxxxxxxxx remplacer les xxx par l'adresse du SAS, collé sur un sticker vert pâle sur la carte. bin Yes/No라고 물으면 Y입력 재부팅 후 사용하던 OS로 부팅. sas2flsh -o -sasadd 500xxxxxxxxxxxxx (replace this address with the one you wrote down in the first steps). Mit dem Befehl "sas2flsh -o -f 2118ir. Will be used as centralized home storage, with some light virtualization and backup duties. Yllä olevan ohjeen kanssa pääsin vaiheeseen, jossa annetaan komento "sas2flsh. sas2flsh -o -sasadd 500605b001bdcc32 5 u: O, j4 }# P- g7 X "500605bxxxxxxxxx" 这个号在你的卡上有一标签上可以找到,500605B开头, 去掉 "-"。. Ask Question with the undocumented command sas2flsh -o -e done sith the dos utility and the -sasadd. sas2flsh -o -f 2118it. bin = IT mode Firmware, change according to which way to flash) sas2flsh - o - sasadd 500605bxxxxxxxxx ( x = numbers for SAS address ) < reboot >. bin если нам не нужен BIOS на контроллере sas2flsh -o -sasadd 500605bxxxxxxxxx (x= символы SAS идентификатора) Перезагружаемся - готово!. Fertig – System neustarten und freuen. You're done When you now reboot you should see the new firmware on the card:. txt and the Manually entered SAS address should be displayed. efi is not recognized as an internal or external command, operable program, or batch file" Verschiedene Revisionen, veschiedene Rootverzeichnisse vom USB, AHCI deaktivieren. If you don't have this, I searched and saw there are bootable linux distros what come with EFI shells. bin -b mptsas2. ko-driver, however stage 9. No drives showing on LSI 2008 SAS + HP SAS Expander. ### START d1851bb004ead848f18f828f8fd48bae #3812 Feature Nice to have include htop #3879 Feature Expected Translate RRD data from collectd into something that we. rom 执行 sas2flsh -o -sasadd 500605b0XXXXXXXX 成功后,重启电脑,进入raid的bios界面,确认已经是IT模式了. Берем блокнот с записанным SAS адресом и вводим его после команды: sas2flsh -o -sasadd. exe -o -f 6GBPSAS. $ sas2flsh -o -sasadd 500605bxxxxxxxxx The "xxxxxxxxx" above is the remaining digits from the sticker that you wrote down earlier. Die Fehlermeldung erscheint bei Hauptplatinen mit UEFI oder auf inkompatiblen Mainboards. bin = IT mode Firmware, change according to which way to flash) sas2flsh - o - sasadd 500605bxxxxxxxxx ( x = numbers for SAS address ) < reboot >. bin 3)把备份的各种序列号写回去. Program SAS address in IT-mode: sas2flsh -o -sasadd 500605bxxxxxxxxx where "500605bxxxxxxxxx" SAS address from small green sticker on yor card, without "-" Despite me missing this, it is humming away nicely in my now converted production box on 5. If SAS address have been changed please type command (in DOS)"sas2flsh. This number is unique per controller and you need to make sure you use your own number! This flashes the 2118it. #freenas IRC Archive. sas2flsh says it cant find a controller sas2flsh -o -sasadd. sas2flsh -o -sasadd 5000112233445566 At first, I had issues getting this to work at all: the UEFI versions would detect the card and attempt to boot it, but fail. rom; Program SAS address in IT-mode where 500605b***** is the code on the green sticker on your RAID card without the "-" with sas2flsh -o -sasadd 500605b***** Done for this time! Enjoy your reflashed LSI 9240-8i which is now an LSI 9211-8i!. Hi Michael, Thanks so much for this, I was getting pretty worried about my FreeNAS install when my old Dell Poweredge T310 with the PERC H200 gave me the "Firmware version 2 does not match driver version 16 for /dev/mps0" in FreeNAS Alert. sas2flsh -o -f 214i4et. efi -o -sasadd 5000112233445566 9> 重启电脑,完成,即可! 大概的流程就是这样了,不出意义都可以正常刷入的了,附件非常适合大众使用. ) There are a couple of things to note here. rom sas2flsh -o -sasadd 500605b0XXXXXXXX # reboot, fertig ! # X = Nummer der SAS Adresse des Controllers OHNE die “-” Zeichen # -b mptsas2. 6a+ compatible controller. FreeNode #freenas irc chat logs for 2015-02-17. Now power-off the server, so the new BIOS & Firmware are properly loaded, and make sure to change back your Boot option in the server BIOS to your USB key or harddrive that contains the vSphere hypervisor. The H310 in IT mode works great with the $10 HP SAS Expander with the latest HP 2. 执行 sas2flsh -o -f 214i4et. rom (sas2flsh -o -f 2118it. sas2flsh -o -sasadd 500605b***** 以上で書き換えは終了します。 マザーボードとの組み合わせによっては5番のコマンド1行で済むケースもある様ですので、まず最初に5番のコマンドを試してダメだった場合に1番からやって見ても良いかもしれません。. exe -o -sasadd 50030480070a8b00. Substituting the 500605XX… string with your address noted earlier; Reboot and you're done; If you want to do step 12 in the DOS command line, I'll let you guess how you have to change the two requisite commands in substeps 3 and 4. exe -o -sasadd 500xxxxxxxxxxetc. Program SAS address in IT-mode: sas2flsh -o -sasadd 500605bxxxxxxxxx where "500605bxxxxxxxxx" SAS address from small green sticker on yor card, without "-" Despite me missing this, it is humming away nicely in my now converted production box on 5. rom = kann man weglassen, wenn man kein Option ROM (BIOS) benötigt, bootet. – sas2flsh -o -sasadd DeineAdresse z. Need help with H200, FreeNAS, and Dell R710 Discussion in ' sas2flsh. 6a+ compatible controller. sas2flsh -o -f 2118it. Firmware cross-grade IBM 1015 to LSI SAS 9210 IT mode Convert the M1015 to an IT mode controller with the latest firmware and no x86 BIOS support (the disks are to be used with FreeBSD and ZFS). - sas2flsh -o -sasadd DeineAdresse z. exe -o -f 2118it. Updating LSI firmware through the ESXi commandline. bin instead of the 6GBPSAS. bin -b mptsas2. bin FW) sas2flsh -o -biosall mptsas2. Quiero montar 2 volúmenes RAID0 por hardware en un pc con windows 10. sas2flsh -o -sasadd 500605b0xxxxxxxx (x= numbers for SAS address) Ik ga dan wel de laatste IT firmware gebruiken van de LSI site dus fingers crossed vanavond. 如何将LSI9240(IBM M1015)改刷IT Mode固件 图1. Program SAS address in IT-mode: sas2flsh -o -sasadd 500605bxxxxxxxxx where "500605bxxxxxxxxx" SAS address from small green sticker on yor card, without "-" All done Smiley Pros: You have low-cost(65$ on ebay), fast, high-quality LSI 9210-8i Unraid 5. you might be right. Die Fehlermeldung erscheint bei Hauptplatinen mit UEFI oder auf inkompatiblen Mainboards. sas2flsh -o -sasadd 500605b0deadbabe Boot and create RAID0 volume using SSD modules with SAS ID's 0, 3, 5 and 7. bin -b mptsas2. efi in this new ZIP file are p5 which allows you to pretty much overwrite/downgrade any firmware. bin # sas2flsh -b mptsas2. The PERC H310 is a pretty standard and widely available PCI express RAID controller. sas2flsh -o -sasadd 500xxxxxxxxxxx. <sas2flshで作業> DOSでブートして sas2flsh -o -f 2118it. bin if OptionROM is not needed) sas2flsh o sasadd bxxxxxxxxx (x numbers for SAS address) Done!Aug 13, 2015 I came across a problem today when I wanted to. bin-b mptsas2. sas2flsh -o -f 6gbpsas. One of the most popular SAS 6. rom Program the SAS address. efi -list and see the card is reported as a SAS 9300-8i with the proper address. rom > sas2flsh -o -sasadd 500605bxxxxxxxxx remplacer les xxx par l'adresse du SAS, collé sur un sticker vert pâle sur la carte. rom > sas2flsh -o -sasadd 500605bxxxxxxxxx remplacer les xxx par l'adresse du SAS, collé sur un sticker vert pâle sur la carte. sas2flsh - o - sasadd 500605bxxxxxxxxx Trong đó 500605bxxxxxxxxx là địa chỉ được tạo ra trong bước trên. sas2flsh -o -e 6 sas2flsh -o -b mptsas2. $ sas2flsh -o -sasadd 500605bxxxxxxxxx The "xxxxxxxxx" above is the remaining digits from the sticker that you wrote down earlier. Dell Perc H310 and NexentaStor 3 minute read I have been using Nexenta for several years now of course. rom sas2flsh -o -sasadd 500605b0xxxxxxxx (x= numbers for SAS address) The SAS address is found on the back of the card, on the green sticker. Voor een nog te bouwen servertje ben ik op zoek naar een losse raidcontroller. fw If flashing a M1015 you can use the 2118p7. rom(Update bios Ver). bin -b mptsas2. rom 6)更新 sas2flsh -o -sasadd 500605b0xxxxxxxx (x= numbers for SAS address) Done! 成功後 刷成 9211-8i 如附圖 有錯請指正 以上,感謝~. sas2flsh -o -sasadd 500605bxxxxxxxxx (x= numbers for SAS address) Done! I thought this^ above was a little less clear so I provided the extra in the steps above for basic help so a newbie will know what to do without making the mistakes that are common. Có thế khi người ta đọc vào không hiểu. If you have a motherboard that uses UEFI instead of a legacy BIOS, use the following process to update the firmware on your LSI controller. Flash the new firmware: sas2flsh -o -f 2118ir. Program SAS address in IT-mode: sas2flsh -o -sasadd 500605bxxxxxxxxx where "500605bxxxxxxxxx" SAS address from small green sticker on yor card, without "-" All done Smiley Pros: You have low-cost(65$ on ebay), fast, high-quality LSI 9210-8i Unraid 5. P20版本 20160906:本帖是一篇简单的介绍可能会有不明白的地方建议大伙可以直接参考以下链接做进一步了解. sas2flsh -o -sasadd 500605b0xxxxxxxx. sas2flsh -o -sasadd 500605b0xxxxxxxx (x= numbers for SAS address) Probaltam DOS-bol, efi-bol is ugyan ez a gond. Берем блокнот с записанным SAS адресом и вводим его после команды: sas2flsh -o -sasadd. sas2flsh -o -f 2118ir. bin sas2flsh -o -sasadd 500. Llegados a este punto, o tenemos una HBA, o algo con que sujetar la puerta. sas2flsh -o -sasadd 500605b0xxxxxxxx (x= numbers for SAS address) Ik ga dan wel de laatste IT firmware gebruiken van de LSI site dus fingers crossed vanavond. sas2flsh -o -f 2118it. Congratulations, you are ready to go after a reboot. Now power-off the server, so the new BIOS & Firmware are properly loaded, and make sure to change back your Boot option in the server BIOS to your USB key or harddrive that contains the vSphere hypervisor. IT-mode Wink. Redémarrer Fini! Petit Bonus: Si vous choisissez le mode IT, il n'y a plus d'intérêt à charger le bios de la carte (puisqu'aucune action n'est possible!). efi in this new ZIP file are p5 which allows you to pretty much overwrite/downgrade any firmware. exe -listall (to find adapter number… usually "0") 2) sas2flsh. bin FW) sas2flsh -o -biosall mptsas2. So I'm not sure why I retyped all of this instead of just updating the ZIP file in the old guide. bin -b mptsas2. rom sas2flsh -o -sasadd 500605b0XXXXXXXX # reboot, fertig ! # X = Nummer der SAS Adresse des Controllers OHNE die "-" Zeichen # -b mptsas2. sas2flash. You're done. bin если нам не нужен BIOS на контроллере sas2flsh -o -sasadd 500605bxxxxxxxxx (x= символы SAS идентификатора) Перезагружаемся - готово!. bin,注意改成正确的文件名。 可以用DIR命令查看U盘中文件名. As alternative sas2flsh tool exists for linux and all the sas2flsh steps could be done from comfort of your Linux distro. bin -b mptsas2. efi -o -sasadd 500605b[THE REST OF YOU ADDRESS WITHOUT HYPHENS] To flash other modes take a look at Pieter's post on the top. The motherboard i used for flashing was a MSI X48 Platinum. rom (sas2flsh -o -f 2118it. exe -o -f 6GBPSAS. Obviously the address has to be 16 digits and the 9th digit is most likely always 0, but one has to realize that actually you HAVE to go against the instructions to be succesfull. Download the file to a folder on your hard drive, then double-click it to unzip the set of files. Convert LSI9240(IBM M1015) to a LSI9211-IT mode Type in the following exactly: megarec -writesbr 0 sbrempty. In the last few years Microsoft has moved the storage system of choose from raid controllers to the simpler just a butch of disk (JBOD) storage solution. sas2flsh -o -sasadd 500xxxxxxxxxxx. bin megarec -cleanflash 0 # reboot, wieder vom USB Stick sas2flsh -o -f 2118it. But I guess when you have an older motherboard with which sas2flsh. Voor een nog te bouwen servertje ben ik op zoek naar een losse raidcontroller. Note: applicable to M1115 and similar LSI SAS2008 chips. Có người nói với tôi rằng, khi làm một bài hướng dẫn cứ viết ngăn ngắn, không tội gì phải viết cặn kẽ dài dòng. Will be used as centralized home storage, with some light virtualization and backup duties. exe -o -sasadd xxxxxxxxxxxxx(아까 적어둔 SAS ADDRESS입력) 재부팅 후 다시 Freedos USB로 부팅 sas2flsh. bin FW) sas2flsh -o -biosall mptsas2. bin sas2flsh -o -sasadd 500605bxxxxxxxxx. #freenas IRC Archive. rom(Update bios Ver). bin if OptionROM is not needed) sas2flsh -o -sasadd 500605bxxxxxxxxx (x= numbers for SAS address) Jag fastnat dock på raden. Exiting program" on my SuperMicro X10 motherboard when trying to do anything with that tool in DOS. bin -c 0 sas2flsh -o -f 2118it. sas2flsh -o -sasadd 500605b0xxxxxxxx. exe -o -f 6GBPSAS. C:\> s2fp19. Program SAS address in IT-mode: sas2flsh -o -sasadd 500605bxxxxxxxxx where "500605bxxxxxxxxx" SAS address from small green sticker on yor card, without "-" All done Smiley Pros: You have low-cost(65$ on ebay), fast, high-quality LSI 9210-8i Unraid 5. However, if it needs input to. sas2flsh -o -f 2118ir. [[email protected] ~]# lspci|grep LSI. So hat es bei meiner Perc H310 funktioniert, wobei die. sas2flsh -o -f 2118it. Since then I've been having strange issues with my IBM M1015 controller. net元スレ自作PC板に戻る全部最新50 終了したスレッドです. bin -b mptsas2. exe -o -f 6GBPSAS. PAN Fehler : Entweder älteres Board nehmen oder per EFI flashen. sas2flsh -o -f 2118it buy cytotec online. The dos4gw application allows these applications to address more memory space than they would be able to otherwise, but you won't need to run it directly. Reboot the computer and boot back into the USB drive. exe -o -sasadd 500xxxxxxxxxxetc. If you don't have this, I searched and saw there are bootable linux distros what come with EFI shells. On the lsi webpage I found mpslsi. FreeNode #freenas irc chat logs for 2015-02-17. bin instead of the 6GBPSAS. FreeNode #freenas irc chat logs for 2016-11-06. efi -o -sasadd 500605b[THE REST OF YOU ADDRESS WITHOUT HYPHENS] To flash other modes take a look at Pieter's post on the top. (500605b001f31fa0) 9. exe -o -sasadd "Controller SAS address" For example: sas2flsh. ##IBM ServeRAID M1015: crossflashing to a LSI9211-8i IR/IT Mode. sas2flsh -o -sasadd xxxxxxxxxxxxxxxx (where x's equal your card's real SAS address) ### Step 14 may be redundant and therefore omitted since step 18 essentially does the same thing?. Die x durch die notierten Zeichen ersetzen (SAS Adresse) Stick entfernen und den Rechner neustarten. exe -o -sasadd 5xxxxxxxxxxxxxxx Achtung! Mögliche -(Bindestriche) weglassen. fw #das muss mit dem originalen Dell-package P7 gemacht werden, klappt sonst nicht! sas2flsh. sas2flsh -o -sasadd 5000112233445566 At first, I had issues getting this to work at all: the UEFI versions would detect the card and attempt to boot it, but fail. If you're using UEFI, the sas2flsh commands are executed from a EFI-shell as opposed to the DOS-environement we were in earlier. exe -o -sasadd xxxxxxxxxxxxx(아까 적어둔 SAS ADDRESS입력) 재부팅 후 다시 Freedos USB로 부팅 sas2flsh. FreeNode #freenas irc chat logs for 2015-02-17. Exiting program" on my SuperMicro X10 motherboard when trying to do anything with that tool in DOS. sas2flsh -o -f 2108it. Ask Question with the undocumented command sas2flsh -o -e done sith the dos utility and the -sasadd. Es para editar vídeo. Syntax: sas2flash o sasadd 50062b000000000 sas2flash o sasadd 0x50062b000000000. You're done When you now reboot you should see the new firmware on the card:. rom sas2flsh -o -sasadd 500605bxxxxxxxxx where the xxxx stuff is from the back of my card. bin Yes/No라고 물으면 Y입력 재부팅 후 사용하던 OS로 부팅. IMPORTANT for the R510) 2) sas2flsh. sas2flsh -o -sasadd 500605bxxxxxxxxx (x= numbers for SAS address) sas2flsh -o -sasadd 500605b0xxxxxxxx (x= numbers for SAS address) Other on has 9 x's, other 8. Fertig! Fehler beim Flashen. efi -o -sasadd 500605bxxxxxxxxx 注意应更正两个地方,一个是sas2flsh更改成sas2flash, 2108. bin controller firmware and the mptsas2. sas2flsh -o -f 214i4et. rom; Program SAS address in IT-mode where 500605b***** is the code on the green sticker on your RAID card without the "-" with sas2flsh -o -sasadd 500605b***** Done for this time! Enjoy your reflashed LSI 9240-8i which is now an LSI 9211-8i!. You're done. ### START d1851bb004ead848f18f828f8fd48bae #3812 Feature Nice to have include htop #3879 Feature Expected Translate RRD data from collectd into something that we. fw If flashing a M1015 you can use the 2118p7. bin -b mptsas2. Program SAS address in IT-mode: sas2flsh -o -sasadd 500605bxxxxxxxxx where "500605bxxxxxxxxx" SAS address from small green sticker on yor card, without "-" All done Smiley Pros: You have low-cost(65$ on ebay), fast, high-quality LSI 9210-8i Unraid 5. Flash the card with the LSI 9211-8i Firmware. FreeNode #freenas irc chat logs for 2015-02-17. Ask Question with the undocumented command sas2flsh -o -e done sith the dos utility and the -sasadd. När man försöker köra med sas2flsh -list så. Rest are duplicates, perhaps SSD modules are actually dual ported SAS rathern than SATA like everyone assumes. The final working process involved doing the megarec commands on a consumer motherboard and then running the sas2flsh commands directly on the R710 as follows: sas2flsh. Flashing the IBM ServeRAID M1015 to the LSI9211 October 24, 2017 August 17, 2015 by Anthony D The IBM ServeRAID M1015 is an enterprise SAS controller that is very capable in a home server and can be had for around $100 on eBay. rom 执行 sas2flsh -o -sasadd 500605b0XXXXXXXX 成功后,重启电脑,进入raid的bios界面,确认已经是IT模式了. efi in this new ZIP file are p5 which allows you to pretty much overwrite/downgrade any firmware. rom sas2flsh -o -sasadd 500605b0XXXXXXXX # reboot, fertig ! # X = Nummer der SAS Adresse des Controllers OHNE die “-” Zeichen # -b mptsas2. exe -o -sasadd 50030480070a8b00 4) Reboot the system Flashing IR mode in UEFI mode 1) Please copy all files from UEFI folder to bootable USB disk 2) Run SMC2308R. bin-b mptsas2. bin (失败就可以往下执行) megarec -cleanflash 0(将阵列卡信息清空) 重启. exe theoretically does work, this "No LSI SAS adapters found!". bin -b mptsas2. Convert LSI9240(IBM M1015) to a LSI9211IT mode Type in the following exactly: megarec writesbr 0 sbrempty. Using the sas2flash. Juuh elikkäs. rom sas2flsh -o -sasadd 500605bxxxxxxxxx (500605bxxxxxxxxxは上記のボードからメモったaddressを記載) 再度、再起動します。 コレでHBA化は完了しているはずです。. exe - утилита для работы с контроллерами LSI, образы BIOS и firmware (в контроллерах на базе LSI 2008 bios и fw шьются отдельно) 2. One of the most popular SAS 6. bin = IT mode Firmware, change according to which way to flash) sas2flsh -o -sasadd 500605bxxxxxxxxx (x= numbers for SAS address). Syntax: sas2flash o sasadd 50062b000000000 sas2flash o sasadd 0x50062b000000000. C:\> s2fp19. Now power-off the server, so the new BIOS & Firmware are properly loaded, and make sure to change back your Boot option in the server BIOS to your USB key or harddrive that contains the vSphere hypervisor. It attempts to run without prompting you for input. sas2flsh -o -f 2118it. #freenas IRC Archive. command, or the sas2flsh command in DOS, to invoke the utility. bin -b mptsas2. Flash the new firmware: sas2flsh -o -f 2118ir. Flashing the IBM ServeRAID M1015 to the LSI9211 October 24, 2017 August 17, 2015 by Anthony D The IBM ServeRAID M1015 is an enterprise SAS controller that is very capable in a home server and can be had for around $100 on eBay. efi is not recognized as an internal or external command, operable program, or batch file" Verschiedene Revisionen, veschiedene Rootverzeichnisse vom USB, AHCI deaktivieren. megarec -writesbr 0 sbrempty binmegarec -cleanflash 0< reboot back to USB stick Ya hemos acabado. Look at Logs/Adapter. If you continue to use this site we will assume that you are happy with it. exe theoretically does work, this "No LSI SAS adapters found!". ) There are a couple of things to note here. – sas2flsh -o -sasadd DeineAdresse z. efi -listall command now shows us the new Firmware and BIOS applied to both cards. exe -c 0 -list (ensure it's your address, and not all zeros) 3) reboot and enjoy. Juuh elikkäs. sas2flsh -o -f 2118it. Final reboot and the card is good to go. bin if OptionROM is not needed) sas2flsh -o -sasadd 500605bxxxxxxxxx (x= numbers for SAS address) Jag fastnat dock på raden. _jkh_: nik_: I mean, if you're going to punch the HDs through then that certainly removes some of the classic caveats (ZFS likes to own the disks directly) but without more to the picture, ESXi doesn't really add anything either, unless your hardware is just grossly overspec'd and you want to use it for multiple VMs. megarec -writesbr 0 sbrempty. rom(Update bios Ver). No drives showing on LSI 2008 SAS + HP SAS Expander. efi -o -sasadd 500605b0xxxxxxxx (x= numbers. Is there any difference with this that i found in another guide : To erase the firmware but not erase all the cards info completey eg it's SAS address, Hardware ID etc) enter the command :. Sau bước này chúng ta đã hoàn thành quá trình flash lại IT firmware cho các card RAID thông dụng và chi phí rẻ. 6a+ compatible controller. Tuotteen toimintalämpötila ja tuo ilmoittamasi maksimilämpötila ovat kaksi täysin eri asiaa. Käyttäjänimimerkin makke95 SSD käy noissa. #freenas IRC Archive. exe - утилита для работы с контроллерами LSI, образы BIOS и firmware (в контроллерах на базе LSI 2008 bios и fw шьются отдельно) 2. sas2flsh -o -f 2118it. bin Yes/No라고 물으면 Y입력 재부팅 후 사용하던 OS로 부팅. Het is mij opgevallen dat slechts weinig ITX moederborden 6 SATA. Congratulations, you are ready to go after a reboot. bin -b mptsas2. exe and sas2flash. You're done. P20版本 20160906:本帖是一篇简单的介绍可能会有不明白的地方建议大伙可以直接参考以下链接做进一步了解. I was trying to get an H200 flashed and running in a Dell R710 and after flashing I could not get it to appear as a boot device no matter what I did. exe -o -sasadd 5xxxxxxxxxxxxxxx Achtung! Mögliche -(Bindestriche) weglassen. sas2flsh -o -f 2118it. exe -o -sasadd xxxxxxxxxxxxx(아까 적어둔 SAS ADDRESS입력) 재부팅 후 다시 Freedos USB로 부팅 sas2flsh. megarec -writesbr 0 sbrempty. _jkh_: nik_: I mean, if you're going to punch the HDs through then that certainly removes some of the classic caveats (ZFS likes to own the disks directly) but without more to the picture, ESXi doesn't really add anything either, unless your hardware is just grossly overspec'd and you want to use it for multiple VMs. efi is not recognized as an internal or external command, operable program, or batch file" Verschiedene Revisionen, veschiedene Rootverzeichnisse vom USB, AHCI deaktivieren. Drop the resulting sas2flash. bin # (if OptionROM is not needed) sas2flsh -o -sasadd 500605bxxxxxxxxx (x= numbers for SAS address) In my case, I chose not to install the mptsas2. txt and the Manually entered SAS address should be displayed. bin -b mptsas2. sas2flsh -o -f 2118it. bin sas2flsh -o -sasadd 500605bxxxxxxxxx. Preparing an LSI SAS 2008 based controller for ZFS In my last post I wrote about how the Adaptec 5805 RAID controller was the wrong choice for our backup server. Set controller SAS address (replace 500605bxxxxxxxxx with the actual SAS address of your controller): sas2flsh -o -sasadd 500605bxxxxxxxxx 11. Flashing the IBM ServeRAID M1015 to the LSI9211 October 24, 2017 August 17, 2015 by Anthony D The IBM ServeRAID M1015 is an enterprise SAS controller that is very capable in a home server and can be had for around $100 on eBay. efi in this new ZIP file are p5 which allows you to pretty much overwrite/downgrade any firmware. exe -listall and "Write down the SAS Address and continue to the next steps"? You can manually add a SAS Address to the card using "-sasadd". (the controllers SAS address) After seeing so many failed attempts to flash this controller to IT mode, I just wanted to show everyone that it is possible to flash the Fujitsu D2607 to IT mode. If you're using UEFI, the sas2flsh commands are executed from a EFI-shell as opposed to the DOS-environement we were in earlier. 执行 sas2flsh -o -f 214i4et. Program SAS address in IT-mode: sas2flsh -o -sasadd 500605bxxxxxxxxx where "500605bxxxxxxxxx" SAS address from small green sticker on yor card, without "-" All done Smiley Pros: You have low-cost(65$ on ebay), fast, high-quality LSI 9210-8i Unraid 5. So hat es bei meiner Perc H310 funktioniert, wobei die. Is there any difference with this that i found in another guide : To erase the firmware but not erase all the cards info completey eg it's SAS address, Hardware ID etc) enter the command :. bin megarec -cleanflash 0 # reboot, wieder vom USB Stick sas2flsh -o -f 2118it. sas2flsh-o-sasadd 500605bxxxxxxxxx Trong đó 500605bxxxxxxxxx là địa chỉ được tạo ra trong bước trên. exe -o -sasadd "Controller SAS address" For example: sas2flsh. efi -o -sasadd 50060XXXXXXXXXXXX. sas2flsh -o -f 2118it. In the last few years Microsoft has moved the storage system of choose from raid controllers to the simpler just a butch of disk (JBOD) storage solution. And that's it! If all went well on your next reboot, your card should come online as a simple HBA pass through! Restoring the controller back to factory defaults. bin-b mptsas2. rom (2118it. exe -o -sasadd 5xxxxxxxxxxxxxxx (to replace SAS address you wrote down) #Check to make sure your correct SAS address is present: 1) sas2flsh. megarec -writesbr 0 sbrempty. bin,注意改成正确的文件名。 可以用DIR命令查看U盘中文件名. serían 4 discos SATA3 hitachi de 4tb cada uno para un volumen y 4 discos SATA3 toshiba de 2tb cada uno para el otro volumen.